SERIES 2000 FRYER MANUALINSTANT RECOVERY®GAS FRYERREAD AND SAVE THIS MANUAL FOR FUTURE REFERENCERecord the Model No. and Serial of this Instant Recove
85. Open the discard valve located near the quick dis-connect in the filter cabinet.6. The hose may now be used to pump the oil into theshortening han
PREVENTIVE MAINTENANCEPreventive maintenance should be done in daily, week-ly, monthly and yearly intervals as necessary. Followingpreventive maintena
REQUIRED TEST EQUIPMENT:Multimeter (for testing continuity)CHECKING CONTINUITY WITH THE MULTIMETER1. Rotate the thermostat shaft until an audible clic
STEP 2 PRESS all 3 buttons in sequence: left-center-right.The BEEPER will BEEP when each button ispressed. If BEEPER does not BEEP, the timer isdefect
QTY. DESCRIPTION PART #A 1 THERMOSTAT DIAL PLATE 375° 058037B 1 THERMOSTAT KNOB 004163C 1 GAS FRYER THERMOSTAT14” 14CM and AA 02314510x11 18 and up 03
ELECTRICAL BOX ASSEMBLY GAS FRYER(TS and BB ONLY)QTY. DESCRIPTION P/NA 1 TRANSFORMER 120V/240V TO 24V 032408B 1 2 PIN CONNECTOR 032207C 1 9 PIN CONNEC
POT ASSEMBLY 18BB & 18TS GAS(Front Drain Shown)QTY. DESCRIPTION P/NA 4 3 FIN RADIANT 000041B 1 POT 18” GAS WELDMENT Call 800-KEATINGC 4 BURNER 028
15AA2000 ELECTRICAL ASSEMBLYBB2000 ELECTRICAL ASSEMBLY
16Electrical Assembly not shown to scaleTS2000 ELECTRICAL ASSEMBLYElectrical Assembly not shown to scaleBB ELECTRICAL ASSEMBLY WITH SE FILTER
17TS ELECTRICAL ASSEMBLY WITH SE FILTERBASKET LIFT ELECTRICAL ASSEMBLY (ALL FRYERS)
iImproper installation,adjustment, alteration, service or maintenance can cause property damage, injury or death.Read the installation, operating and
18PROBLEM PROBABLE CAUSE SOLUTIONFryer overshoots a. Thermostat bulb improperly a. Adjust bulb position. See page 9 – temperature setting. placed. Th
KEATING LIMITED WARRANTY CARDPLEASE COMPLETE AND MAIL AT ONCE–WARRANTY IS NOT IN EFFECT UNTIL CARD IS RETURNED.WARRANTY CARD IS ALSO AVAILABLE TO COMP
INTRODUCTIONInstructions in this manual should be read thoroughlybefore attempting to operate this Keating Gas Fryer. Allinstallation and service on K
2only on the type of gas specified by the user and indi-cated on the serial plate located inside the door. Thegas may be natural, propane or manufactu
3receptacle. Do not cut or remove the grounding prongfrom this plug. (Model AA has no electric connection).LEVELINGThe Keating Gas Fryer will operate
4AA CONTROL PANELBB CONTROL PANEL34×24 BB CONTROL PANEL34×24 TS CONTROL PANELTS CPU CONTROL PANELAIR IN THE GAS SUPPLY LINE MAY REQUIRE ALONGER THAN N
STEP 1. Set "MELT-IDLE-FRY" switch to "IDLE" posi-tion and thermostat to the "OFF" position.STEP 2. Turn "MAIN POWE
6CCAAUUTTIIOONNOPERATION OF THIS FRYER SHOULD BE LIMITEDTO PERSONNEL WHO HAVE BEEN THOROUGHLYTRAINED IN OPERATING PROCEDURES.Set thermostat to the des
CCAAUUTTIIOONNA KEATING FRYER OR FILTER SHOULD BE DRAINEDONLY UNDER THE SUPERVISION OF PROPERLYTRAINED PERSONNEL. WHEN DISCARDING OIL, ACOVERED RECEPT