MG-2/MG-4
GAS HOT
PLATE
SERVICE
MANUAL
KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL
1-800-KEATING
www.keatingofchicago.com
Hot Plate 0107 09/07
Vista de pagina 0
1 2 3 4 5 6 ... 12 13

Indice de contenidos

Pagina 1 - MG-2/MG-4

MG-2/MG-4GAS HOTPLATE SERVICEMANUALKEEP THIS MANUAL FOR TRAINING NEW PERSONNEL1-800-KEATINGwww.keatingofchicago.comHot Plate 0107 09/07

Pagina 2 - TABLE OF CONTENTS

7HOT PLATE ASSEMBLYNOTE: MG-4 hot plates are built as twoMG-2 hot plates side by side. The MG-2 isshown here.NOTE: Part numbers correspond with theHo

Pagina 3 - YOUR UNIT

8VIII WIRING DIAGRAMSMG SI WIRING AND LADDER DIAGRAMSThe diagrams below apply to hot plates with spark ignition (“SI”). Hot plates with constant pil

Pagina 4 - I INTRODUCTION

LIMITED WARRANTYKeating Of Chicago, Inc. ("Keating”) warrants to the original purchaser. ("Customer"), all new Keating Fryers, Filter S

Pagina 5 - II INSTALLATION

SERVICE INFORMATIONIf you have a service related question call 1-800-KEATING.Please state the nature of the call; it will ensure speaking with the app

Pagina 6 - GAS LEAK TESTING

SECTION I INTRODUCTIONGeneral Information . . . . . . . . . . . . . . . . . . . . . . . . .1Ratings . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 7 - IV MAINTENANCE

POST THIS LABEL IN APROMINENT LOCATION ONYOUR UNITiIMPORTANTIN THE EVENT A GAS ODOR IS DETECTED,SHUT DOWN UNITS AT MAIN SHUT OFF VALVEAND CONTACT THE

Pagina 8 - VII PARTS LISTS

I INTRODUCTIONGENERALKeating MG-2 and MG-4 Hot Plates are designed togive maximum production efficiency; delivering highquality food products. The fol

Pagina 9 - GAS HOT PLATE PARTS LIST

2 THIS HOT PLATE MAY NOT BE ALTERED,MODIFIED OR CHANGED IN ANY WAY.The State of California enacted the California Safedrinking water and Toxic Enforc

Pagina 10 - HOT PLATE ASSEMBLY

testing at test pressures less than to equal to 1/2 psig(3.45 KPA), hot plate must be isolated from gas supplypiping. When pressure testing at test pr

Pagina 11 - VIII WIRING DIAGRAMS

4WARNINGPROPANE GAS MAY EVENTUALLY LOSE ITS ODORAND PRECAUTIONS SHOULD BE TAKEN TOASSURE THAT IT IS NOT PRESENT EVEN THOUGHYOU DO NOT DETECT AN ODOR.

Pagina 12 - WARRANTY

V SERVICE DIAGNOSIS On constant pilot models, the pilot light will bebetween 3/8" to 1/2" high and burn clear blue. Theconstant pilot consu

Pagina 13

6GAS HOT PLATE PARTS LISTPARTITEM DESCRIPTION MG-2 MG-4 NUMBER1 GAS VALVE (INFINITE CONTROL) WITH NG ORIFICE #49CONSTANT PILOT 2 4 002666SPARK IGNITO